Wall mount for the IQ SENSOR NET system (Quantity: 1). | ||||
Specific two-wire IQ SENSOR NET cable with shield for safe power/information transfer within the IQ SENSOR NET system, 20 meters length (Quantity: 1). | ||||
Sensor adapter cable for all IQ sensors, with IP 68 waterproof connection to the IQ SENSOR NET system. Cable length 20 m (Quantity: 1). | ||||
Installation set for mounting of up to six on-line sensors. Supplied with: 6 sensor holder EH3/U 170; SensorClean swing mounting EH/F 170-1,5; Vario floor mounting stand BE/ST 170; Sun shield SSH/IQ (Quantity: 1). |
6 analog outputs (0/4-20 mA) for the 2020 3G, 282/284 terminals | ||
Number of occupied output channels is 6 | ||
The six current outputs can be programmed as: Analog output (recorder) and/or PID regulator | ||
The user can link current outputs to sensors. The linked current outputs can be used to monitor sensors or for control purposes | ||
Quantity: 1 |
Certifications | IP-66, equivalent to NEMA 4X |
Connectivity / Communications | 282/284 terminals, 6 analog outputs (0/4-20 mA) for the 2020 3G |
Integrated Lightning Protection | Yes |
Languages | English |
Operating Temperature | -20 to 55 °C |
Smart Sensors / Ports | Yes |
Storage Temperature | -25 to 65 °C |
Warranty | 3 Years |
Measuring method | Potentiometric |
Measuring range (25 °C) | 0.00 ... 14.00 pH (depending on the electrode) |
± 2000mV (depending on the electrode) | |
Resolution | 0.01 pH |
1mV | |
Accuracy | Depends on calibration |
± 0.2 pH; ± 20 mV | |
Temp. measurement | Integrated NTC, -5 ... +60 °C |
Temp. compensation | 0... +60 °C |
Pressure Resistance | 10 bar |
Ambient Conditions | Operating temperature: 0... +60 °C |
Electrical connections | 2-wire shield cable with quick fastener to sensor |
Quantity: | 1 |
Measuring method | Optical |
Measuring range (25 °C) | O2 concentration: 0 ... 20.00 mg/l (0 ... 20.00 ppm) |
O2 saturation: 0 ... 200.0 % | |
Resolution | O2 concentration: 0.01 mg/l (0.01 ppm) |
O2 saturation: 0.1 % | |
Accuracy | < 1 mg/l (ppm): ± 0.05 mg/l (ppm) |
> 1mg/l (ppm): ± 0.1 mg/l (ppm) | |
Response time at 25 °C | t90: < 150 s |
t95: < 200 s | |
Temp. measurement | Integrated NTC, 23 °F ... 140 °F (-5 °C ... +60 °C) ± 0.5 °C |
Temp. compensation | 23 °F ... 122 °F (-5 °C ... +50 °C) |
Pressure Resistance | 10 bar (incl. sensor connection cable) |
Ambient Conditions | 23 °F ... 122 °F (-5 °C ... +50 °C) |
-13 °F ... 122 °F (-25 °C ... +50 °C) | |
Electrical connections | 2-wire shield cable with quick fastener to sensor |
Quantity: | 1 |
Measuring method | Nephelometric principle in compliance with EN ISO 7027 |
Measuring range | FNU; NTU; TEF: 0 ... 4000 FNU |
mg/l SiO2; ppm SiO2: 0.1 ... 4000 mg/l SiO2 | |
g/l TS: 0.0001 ... 400 g/l TS | |
Resolution | FNU; NTU; TEF: Automatic according to measuring range 0.001 ... 1 FNU |
mg/l SiO2; ppm SiO2: 0.001 mg/l ... 0.01 g/l | |
g/l TS: 0.001 mg/l … 1 g/l | |
Accuracy | Process variation coefficient according to DIN 38402 part 51 <1 % (in the range up to 2000 FNU) |
Repeatability according to DIN ISO 5725 or DIN 1319 < 0.015 % or ≥ 0.006 FNU | |
Calibration | FNU; NTU; TEF: Factory calibration with formazine |
mg/l SiO2; ppm SiO2: Factory calibration with SiO2 | |
g/l TS: Calibration by user, (TSS regulations in compliance with DIN 38414) | |
Cleaning System | Ultrasound cleaning system |
SensCheck | Contamination detection of optical window; failure of cleaning system |
Pressure Resistance | 10 bar (incl. sensor connection cable) |
Ambient Conditions | Operating temperature: 0 ... 60 °C |
ultrasonic cleaning system: 0 ... 40 °C (overheating protection) | |
Storage temperature: -5 ... +65 °C | |
Electrical connections | 2-wire shield cable with quick fastener to sensor |
Quantity: | 1 |
Measuring method | Conductometric (4-electrode cell) |
Measuring range | 10 μS/cm - 500 mS/cm |
SAL: 0 … 70 | |
TDS: 0 … 2000 mg/l | |
Accuracy | ± 2 % of measured value ± 1 Digit (in standard solution, 25 °C, with non-linear temp. comp. (acc. DIN 38404)) |
Cell Constants | K = 0.917 cm-1, ±1.5% (in free solution) |
K = 0.933 cm-1 | |
Temp. measurement | -5 ... +60 °C |
Temp. compensation | linear: 0 ... +60 °C |
nonlinear: +5 °C … 35 °C | |
nonlinear: +35 °C … +60 °C | |
Pressure Resistance | 10 bar |
Ambient Conditions | -5 ... +60 °C |
Electrical connections | 2-wire shield cable with quick fastener to sensor |
Quantity: | 1 |
Wall mount for the IQ SENSOR NET system (Quantity: 1). | ||||
Specific two-wire IQ SENSOR NET cable with shield for safe power/information transfer within the IQ SENSOR NET system, 20 meters length (Quantity: 1). | ||||
Sensor adapter cable for all IQ sensors, with IP 68 waterproof connection to the IQ SENSOR NET system. Cable length 20 m (Quantity: 1). | ||||
Installation set for mounting of up to six on-line sensors. Supplied with: 6 sensor holder EH3/U 170; SensorClean swing mounting EH/F 170-1,5; Vario floor mounting stand BE/ST 170; Sun shield SSH/IQ (Quantity: 1). |